高壓耐壓試驗臺技術說明書
變壓器型號規格 | 容量KVA | 低壓輸入 | 交流高壓輸出 | 直流高壓輸出 kV | 變 比 | ||
電壓 V | 電流 A | 電壓 kV | 電流 mA | ||||
YDJ/TDM-2/50 | 2 | 200 | 10 | 50 | 40 | 70 | 500 |
YDJ/TDM -3/50 | 3 | 200 | 15 | 50 | 60 | 70 | 500 |
YDJ/TDM -5/50 | 5 | 200 | 25 | 50 | 100 | 70 | 500 |
YDJ/TDM -10/50 | 10 | 200 | 50 | 50 | 200 | 70 | 500 |
YDJ/TDM -20/50 | 20 | 400 | 50 | 50 | 400 | 70 | 500 |
YDJ/TDM -30/50 | 30 | 400 | 75 | 50 | 600 | 70 | 500 |
YDJ/TDM -50/50 | 50 | 400 | 125 | 50 | 1000 | 70 | 500 |
YDJ/TDM -100/50 | 100 | 400 | 250 | 50 | 2000 | 70 | 500 |
YDJ/TDM -150/50 | 150 | 400 | 375 | 50 | 3000 | 70 | 500 |
YDJ/TDM -200/50 | 200 | 400 | 500 | 50 | 4000 | 70 | 500 |
YDJ/TDM -5/100 | 5 | 200 | 25 | 100 | 50 | 140 | 1000 |
YDJ/TDM -10/100 | 10 | 200 | 50 | 100 | 100 | 140 | 1000 |
YDJ/TDM -20/100 | 20 | 400 | 50 | 100 | 200 | 140 | 1000 |
YDJ/TDM -30/100 | 30 | 400 | 43 | 100 | 300 | 140 | 1000 |
YDJ/TDM -50/100 | 50 | 400 | 72 | 100 | 500 | 140 | 1000 |
YDJ/TDM -100/100 | 100 | 400 | 375 | 100 | 1000 | 140 | 1000 |
YDJ/TDM -150/100 | 150 | 400 | 72 | 100 | 1000 | 140 | 1000 |
YDJ/TDM -200/100 | 200 | 400 | 144 | 100 | 1000 | 140 | 1000 |
YDJ/TDM -20/150 | 20 | 400 | 288 | 150 | 133 | 210 | 1000 |
YDJ/TDM -30/150 | 30 | 400 | 72 | 150 | 200 | 210 | 1000 |
YDJ/TDM -50/150 | 50 | 400 | 144 | 150 | 333 | 210 | 1000 |
YDJ/TDM -100/150 | 100 | 400 | 288 | 150 | 666 | 210 | 1000 |
YDJ/TDM -150/150 | 150 | 400 | 433 | 150 | 1000 | 210 | 1000 |
YDJ/TDM -50/200 | 50 | 400 | 250 | 200 | 250 | | 1000 |
YDJ/TDM -100/200 | 100 | 400 | 375 | 200 | 500 | | 1000 |
YDJ/TDM -200/200 | 200 | 400 | 500 | 200 | 1000 | | 1000 |
YDJ/TDM -50/300 | 50 | 400 | 50 | 300 | 166 | | 1000 |
YDJ/TDM -100/300 | 100 | 400 | 43 | 300 | 333 | | 1000 |
YDJ/TDM -200/300 | 200 | 400 | 72 | 300 | 666 | | 1000 |
YDJ/TDM -300/300 | 300 | 400 | 250 | 300 | 1000 | | 1000 |
規 格 | 容量(kVA) | 電 源 | 輸 出 | 參考重量(kg) | |||
相數 | 電壓(V) | 頻率(Hz) | 電壓(V) | 電流(A) | |||
XCJH-3 | 3 | 1 | 220 | 50 | 240 | 13.6 | 17 |
XCJH-5 | 5 | 1 | 220 | 50 | 240 | 22.7 | 20 |
HTC-10 | 10 | 1 | 220 | 50 | 240 | 45.5 | 40 |
HTC-15 | 15 | 1 | 220 380 | 50 | 240 430 | 68 39 | 50 |
HTC-20 | 20 | 2 | 380 | 50 | 430 | 52.6 | 55 |
HTC-30 | 30 | 2 | 380 | 50 | 430 | 78.9 | 110 |
HTC-50 | 50 | 2 | 380 | 50 | 430 | 131.5 | 170 |
HTDC-100 | 100 | 2 | 380 | 50 | 450 | 222 | 450 |
HTDC-150 | 150 | 2 | 380 | 50 | 450 | 333 | 1800 |
HTDC-200 | 200 | 2 | 380 | 50 | 450 | 444 | 2800 |
HTDC-250 | 250 | 2 | 380 | 50 | 450 | 555 | 4800 |
HTDC-300 | 300 | 2 | 380 | 50 | | 666 | 5600 |
一、產品概述
YDJ系列超輕型工頻耐壓試驗臺是根據機電部《試驗變壓器》標準在原同類產品基礎上經過大量改進后而生產,是按照國家標準《JB∕T 9641-1999》經過改進后而生產的一種新型產品。YDJ系列工頻耐壓試驗臺產品具有體積小、重量輕、結構緊湊、功能齊全、通用性強和使用方便等特點。工頻耐壓試驗臺特別適用于電力系統、工礦企業、高校電氣科研部門、變壓器電機耐壓修理等對各種高壓電氣設備、電器元件、絕緣材料進行工頻或直流高壓下的絕緣強度試驗。是高壓試驗中必不可少的重要設備打破蘇聯模式,體積非常輕便!YDJ系列工頻耐壓試驗臺采用新日鐵硅鋼片,鐵損低,磁感應強度高,沖片性好,CD鐵芯睡式設計提高防震能力,內注25#專用變壓器絕緣油經過3道高溫真空過濾,MIN進口新型密封圈防滲漏機理,使超輕型高壓試驗變壓器絕緣性能更強,壽命更長,經久耐用。特別設計了自動數字式過電流保護裝置。根據要求可以做大屏幕液晶顯示帶打印功能控制臺。
二、產品結構
YDJ系列工頻耐壓試驗臺采用單框芯式鐵芯結構。初級繞組饒在鐵芯上,高壓繞組在外,這種同軸布置減少了漏磁通,因而增大了繞組間的耦合。產品的外殼制成與器芯配合較佳的八角形結構,整體外形顯得美觀大方。其外部結構圖見圖1,內部結構圖見圖2。
G—球間隙 CX—被試品
注:高壓尾必須可靠接地
工頻耐壓試驗臺試驗中限流電阻R1應根據試驗變壓器的額定容量來選擇。如高壓側額定輸出電流在100~300mA時,可取0.5~1Ω/V(試驗電壓);高壓側額定輸出電流為1A以上時,可取1Ω/V(試驗電壓)。常用水電阻作為限流電阻,管子長度可按150kV/m考慮,管子粗細應具有足夠的熱容量(水阻液配制方法:用蒸餾水加入適量硫酸銅配制成各種不同的阻值)。
球間隙及保護電阻:當電壓超過球間隙整定值時(一般取試驗電壓的110%~120%),球間隙放電,對被試品起到保護作用。球間隙保護電阻可按1Ω/V(試驗電壓)選取。
在工頻耐壓試驗中,低電壓側測量電壓(儀表電壓)不是非常準確的,其原因是由于試驗變
壓器存在著漏抗,在這個漏抗上必然存在著壓降或容升,使試品上的電壓低于或高于低壓側測量電壓表上反映出來的電壓。工頻耐壓試驗時,被試品上的電壓高于試驗變壓器的輸出電壓,也就是所謂容升現象。感應耐壓試驗時,試驗變壓器的漏抗必然存在著壓降。為了準確測量被試品上所施加的電壓,因此常在高壓側接入FRC阻容分壓器來測量電壓(見圖6)。
工頻耐壓試驗臺操作注意事項:
(1) 試驗人員應做好分工,明確相互間聯系方法。并有專門人監護現場安全及觀察試品狀態。
(2) 被試品應先清掃干凈,并絕對干燥,以免損壞被試品和試驗帶來的誤差。
(3) 對于大型試驗,一般都應先進行空升試驗。即不接試品時升壓至試驗電壓,校對各種表計,調整球間隙。
(4) 升壓速度不能太快,并必須防止突然加壓。例如調壓器不在零位時突然合閘。也不能突然切斷電源,一般應在調壓器降至零位時拉閘。
(5) 當電壓升至試驗電壓時,開始計時,到1min后,迅速降壓到1/3試驗電壓以下時,才能拉開電源。
(6) 在升壓或耐壓試驗過程中,如發現下列不正常情況時,應立即降壓,切斷電源。停
(7) 止試驗并查明原因:①電壓表指針擺動很大;②發現絕緣燒焦或冒煙;③被試品內有不正常的聲音。
(8) 耐壓試驗前后應測量絕緣電阻,檢查絕緣情況。
適用范圍: 汽車轉向管、剎車管、空調管、燃油管、冷卻水管、散熱器、 暖風軟管、液壓設備、冷凝器、蒸發器、空調濾芯器軟管、渦輪增壓系統軟管、汽車剎車泵、缸體、工程液壓軟管、航空軟管和管匯、硬管、接頭、閥門、壓力儀表、壓力容器、壓力變送器等。主要技術參數:◎加壓范圍: 400 MPa◎測試工位: 1工位◎測量精度:±0.5%FS(更高精度請致電我司);◎計時范圍:0~999h;◎試驗介質:水、液壓油、或其他液體 (可任選);◎介質溫度:-40℃~150℃±3℃ * (可選項);◎驅動空氣:≤7bar;◎電源電壓:交流220V;◎控制方式:手動控制/PLC控制/計算機控制功能特點:◎主要元器件采用我公司自主生產的成熟產品◎管路系統采用非焊接式連接◎測試流體系統和驅動流體系統分離、方便試驗溫度控制和測試介質多樣化◎采用高速采樣卡(美國NI)采樣試驗數據◎軟件采用LABVIEW編寫◎多種配套工裝,滿足試件不同的安裝方式◎試驗過程中,可以自動進行壓力補償;試件破裂后壓力迅速下降,系統自動停止加壓;◎實現計算機控制功能,可以自由設定充水排氣時間、保壓時間、充氣清洗時間、試驗壓力試驗過程中可以任意設定單段或者多段保壓測試,也可以保壓后直接爆破,升壓速度能保持恒定,可實現無級調節,試驗數據和曲線參數能實時顯示、能自動保存試驗結果、并可任意打印試驗報表;◎特殊設計的防護工裝,能有效保護爆破時對操作人員和設備的傷害。
![]() | ![]() | ![]() | ![]() |
BCJFB工頻耐壓試驗臺 一、 概述 BCJFB工頻耐壓試驗臺是新一代工頻耐壓檢測設備,其性能滿足GB/T 1408.1-2000《低壓開關設備和控制設備總則》及GB 7251.1《低壓成套開關和控制設備部分:型式試驗
變壓器型號規格 | 容量KVA | 低壓輸入 | 交流高壓輸出 | 直流高壓輸出 kV | 變 比 | ||
電壓 V | 電流 A | 電壓 kV | 電流 mA | ||||
YDJ/TDM-2/50 | 2 | 200 | 10 | 50 | 40 | 70 | 500 |
YDJ/TDM -3/50 | 3 | 200 | 15 | 50 | 60 | 70 | 500 |
YDJ/TDM -5/50 | 5 | 200 | 25 | 50 | 100 | 70 | 500 |
YDJ/TDM -10/50 | 10 | 200 | 50 | 50 | 200 | 70 | 500 |
YDJ/TDM -20/50 | 20 | 400 | 50 | 50 | 400 | 70 | 500 |
YDJ/TDM -30/50 | 30 | 400 | 75 | 50 | 600 | 70 | 500 |
YDJ/TDM -50/50 | 50 | 400 | 125 | 50 | 1000 | 70 | 500 |
YDJ/TDM -100/50 | 100 | 400 | 250 | 50 | 2000 | 70 | 500 |
YDJ/TDM -150/50 | 150 | 400 | 375 | 50 | 3000 | 70 | 500 |
YDJ/TDM -200/50 | 200 | 400 | 500 | 50 | 4000 | 70 | 500 |
YDJ/TDM -5/100 | 5 | 200 | 25 | 100 | 50 | 140 | 1000 |
YDJ/TDM -10/100 | 10 | 200 | 50 | 100 | 100 | 140 | 1000 |
YDJ/TDM -20/100 | 20 | 400 | 50 | 100 | 200 | 140 | 1000 |
YDJ/TDM -30/100 | 30 | 400 | 43 | 100 | 300 | 140 | 1000 |
YDJ/TDM -50/100 | 50 | 400 | 72 | 100 | 500 | 140 | 1000 |
YDJ/TDM -100/100 | 100 | 400 | 375 | 100 | 1000 | 140 | 1000 |
YDJ/TDM -150/100 | 150 | 400 | 72 | 100 | 1000 | 140 | 1000 |
YDJ/TDM -200/100 | 200 | 400 | 144 | 100 | 1000 | 140 | 1000 |
YDJ/TDM -20/150 | 20 | 400 | 288 | 150 | 133 | 210 | 1000 |
YDJ/TDM -30/150 | 30 | 400 | 72 | 150 | 200 | 210 | 1000 |
YDJ/TDM -50/150 | 50 | 400 | 144 | 150 | 333 | 210 | 1000 |
YDJ/TDM -100/150 | 100 | 400 | 288 | 150 | 666 | 210 | 1000 |
YDJ/TDM -150/150 | 150 | 400 | 433 | 150 | 1000 | 210 | 1000 |
YDJ/TDM -50/200 | 50 | 400 | 250 | 200 | 250 | | 1000 |
YDJ/TDM -100/200 | 100 | 400 | 375 | 200 | 500 | | 1000 |
YDJ/TDM -200/200 | 200 | 400 | 500 | 200 | 1000 | | 1000 |
YDJ/TDM -50/300 | 50 | 400 | 50 | 300 | 166 | | 1000 |
YDJ/TDM -100/300 | 100 | 400 | 43 | 300 | 333 | | 1000 |
YDJ/TDM -200/300 | 200 | 400 | 72 | 300 | 666 | | 1000 |
YDJ/TDM -300/300 | 300 | 400 | 250 | 300 | 1000 | | 1000 |
規 格 | 容量(kVA) | 電 源 | 輸 出 | 參考重量(kg) | |||
相數 | 電壓(V) | 頻率(Hz) | 電壓(V) | 電流(A) | |||
XCJH-3 | 3 | 1 | 220 | 50 | 240 | 13.6 | 17 |
XCJH-5 | 5 | 1 | 220 | 50 | 240 | 22.7 | 20 |
HTC-10 | 10 | 1 | 220 | 50 | 240 | 45.5 | 40 |
HTC-15 | 15 | 1 | 220 380 | 50 | 240 430 | 68 39 | 50 |
HTC-20 | 20 | 2 | 380 | 50 | 430 | 52.6 | 55 |
HTC-30 | 30 | 2 | 380 | 50 | 430 | 78.9 | 110 |
HTC-50 | 50 | 2 | 380 | 50 | 430 | 131.5 | 170 |
HTDC-100 | 100 | 2 | 380 | 50 | 450 | 222 | 450 |
HTDC-150 | 150 | 2 | 380 | 50 | 450 | 333 | 1800 |
HTDC-200 | 200 | 2 | 380 | 50 | 450 | 444 | 2800 |
HTDC-250 | 250 | 2 | 380 | 50 | 450 | 555 | 4800 |
HTDC-300 | 300 | 2 | 380 | 50 | | 666 | 5600 |
更多產品詳細選型資料請向18615639929 王工索取或咨詢,或登錄www.shinword.com查看,歡迎您的來電。
|
|
|
爆破試驗臺(手動控制) |
|
|
設備參數
1. 適用介質:水、液壓油等大多數液壓介質(特殊介質請咨詢我們)
2. 適合溫度:-45℃~120℃
3. 驅動動力:壓縮空氣(0.7MPa以下,1Nm3/min)
4. 壓力范圍:0-700MPa,(常用壓力范圍0-700MPa)
5. 壓力精度:±1%F.S
6. 流量范圍:0~40L/min
7. 系統全部采用無焊連接,方便拆卸,重復使用,安全可靠
產品特點
1. 采用進口氣動液壓泵產生高壓源,試驗壓力高,最高可達700MPa
2. 根據用戶產品的連接接口特殊設計連接工裝,能方便快速的安裝和拆卸試件
3. 設有一鍵啟動功能,試件安裝后,只需按下一個按鈕,試驗軟件就會按照“充液排氣-升壓-保壓判斷-卸壓”的流程自動完成試驗
4. 試驗過程中,可以自動進行壓力補償,具有測試壓力穩定,壓力測試精度高等優點
5. 試件失效后壓力迅速下降,不會有連續的高壓液體噴出,最大限度保證人身和機器安全
6. 內部結構合理,布局美觀,采用非焊接式管路連接,杜絕跑冒滴漏,而且維修方便
7. 試驗介質可以循環利用;工作介質可以水或油及其他不易揮發\不易爆炸\無腐蝕性液體
8. 試驗倉具有安全防護裝置,并有超壓保護、安全護罩開關等
可選配件
1. 防爆箱:有效保護軟管爆破時對操作人員和設備的傷害。
2. 排氣工裝:試驗前先將試件中的氣體排盡再進行試驗。
5115B型交流電容器耐壓試驗臺是對交流電容器進行引出端間/引出端間與外殼兩種電壓試驗。按國家標準GB3667-2001試驗要求設計,采用電感補償,使輸入電流減小,降低能耗及線路負荷;并通過MCU對電流與電壓進行采樣、漏電流比較,LCD顯示,按鍵操作,具有超漏報警等功能。是適用于交流電容器自愈試驗的專用設備。
性能指標
1.兩引出端間電壓試驗:
l 輸出電壓范圍: AC 0~1.5kV;
l LCD顯示電壓精度:±(3%+5個字);
l 輸出波形: 電源的50Hz/60Hz正弦波;
l試驗電流范圍: 500mA~ 35A,可設步進置;
l試驗電流測試精度: ±(5%+3個字);
2.兩引出端與外殼間電壓試驗:
l 輸出電壓范圍: DC 0~3kV;
lLCD顯示電壓精度:±(3%+5個字);
l漏電流范圍: 0.5mA~ 100mA,可設步進置;
l漏電流測試精度: ±(5%+3個字);
3.定時器定時間: 1~ 99s可設置,步進 +1 s(注:設置“00s”為連續測試);
4.定時器定時精度: ±(3%+2個字);
5.LCD顯示,按鍵操作設置
6.檢測方法: 通過MCU對電流與電壓進行采樣,并用正弦波值進行計算;
l GB3667.1-2005(IEC60252-1:2001)(交流電容器)
lGB3984.1-2004(IEC60110-1:1998)(電磁爐)
lGB/T17702.2-1999(IEC61071-2:1994)(電力電容器)
應用范圍
l 交流電容器生產廠家;
l 空調、電磁爐、汽車蓄電器等生產廠家;
膠管耐壓試驗臺適用于在線檢測鋼絲編織膠管、鋼絲纏繞膠管、動力轉向管、空調管、橡膠軟管、水管等產品的耐壓強度試驗,設備采用觸摸屏控制,設計有工位,提高工人操作效率,試驗完成后吹氣排空。
.產品名稱:FYBP-1000KN鐵路機車空氣彈簧保壓耐壓試驗臺
.產品型號:FYBP-1000KN
.鐵路機車空氣彈簧保壓耐壓試驗臺主要適用范圍及功能:
本試驗機適用于各種鐵路機車空氣彈簧產品的保壓耐壓試驗。
.鐵路機車空氣彈簧保壓耐壓試驗臺主要技術參數: 1、主機最大承載力: <100噸。 2、彈簧最大安裝高度:400MM(矩形鋼材制成) 3、臺面尺寸:1200mm*1000mm(材料45#鋼) 4、彈簧高度上下自動調節范圍:0mm-300mm 5、上固定盤尺寸:(按用戶試樣尺寸定做) 6、下固定墊盤高度及直徑尺寸:(按要求定做) 7、加壓氣源:氣動增壓泵 8、最大實驗壓力:6Mpa 9、壓力調節范圍:0-6Mpa 10、升壓速率調節范圍:0-2Mpa 11、氣壓監測方式:壓力變送器+指針表方式 12、彈簧安裝高度調節方式:液壓式升降 13、液壓缸最大輸出力:100噸 14、液壓油源:集成式液壓站 15、液壓站溢流閥開啟壓力:16mpa 16、液壓閥組控制方式:疊型閥組 17、主機外形尺寸:1200mm*1000mm*1900mm 18、配套液壓站尺寸:600mm*500mm*550mm 19、主機重量:約1050公斤 20、液壓站滿載重量(裝油):300公斤 21、彈簧實驗區防護方式:不銹鋼網隔離 22、控制方式:松下PLC+7寸真彩觸摸屏 23、電氣及氣動控制盤:內置于主機內部 24、樣品測試速度:>2套/小時
.鐵路機車空氣彈簧保壓耐壓試驗臺主要配置: 1、100噸機械主機一臺(周邊帶金屬防護網) 2、氣動增壓回路及附件一套(含增壓泵,閥組,管路,穩壓裝置等) 3、彈簧安裝工裝夾具一套 4、電氣控制系統一套(含觸摸屏,plc、等電氣控制元件) 5、集成液壓站一臺 6、產品說明書一份 7、產品合格證一份